357Executing a Transition
Chapter 3 Transitions
2
Press the [Pattern Limit] button, turning it on.
3
Turn the knobs to adjust the following parameters.
a) 0.00%: Executing the transition does not change the video output at all.
b) 100.00%: The transition is the same as when no pattern limit is set, but the cross-point
button selections of the background A and B buses do not interchange when the transition
completes.
Executing a pattern limit transition
1
Press the [PTN LIMIT] button, turning it on.
The button you pressed lights amber.
2
Carry out the transition.
The transition progresses as far as the set pattern limit. Even if the
transition completes, the cross-point button assignments of the background
A and B buses do not interchange.
3
Carry out the transition once again.
The status before the previous transition is restored.
To cancel the pattern limit
To cancel the pattern limit after completion of step 3 in the previous procedure,
press the [PTN LIMIT] button, turning it off.
If after carrying out step 2 in the previous procedure, the pattern limit has been
reached, carry out the following procedure.
1
Press the [PTN LIMIT] button.
The button you pressed lights green.
2
Carry out the transition.
The [PTN LIMIT] button goes off, and the pattern limit state is released.
Depending on the way in which the transition was executed, the action will
be as follows.
• When you press the [CUT] button, the pattern limit is immediately
released, and the image switches instantaneously.
• When you press the [AUTO TRANS] button, until the state of the next
transition, the transition is carried out over the duration given by the
transition rate.
Knob Parameter Adjustment Setting values
1 Pattern Limit Pattern limit
0.00
a)
to 100.00%
b)