Sony MVS8000 Switch User Manual


 
202
Setup
Chapter 1 MVS-8000 Functions
DME Setup
In DME setup, carry out settings particular to the DME processor.
You can make the following settings.
Input signal settings (Input)
Initial Crop: Make the initial crop setting.
Matte Illeg. Color Limit: Switch the illegal limiter for the signal generated
by the DME internal matte generator on or off.
System Phase: Adjust the operation timing of the whole system with respect
to the reference signal.
TBC Center: Set the TBC window center position.
Output signal settings (Output)
These settings are possible only when the DME is an MVE-9000 or SDI-
interfaced MVE-8000A.
Monitor Output: Set the signals output from the four monitor output
connectors.
Clip Adjust: Adjust the clip levels of DME1 and DME2 outputs.
Interface with external devices (Device Interface)
Editor Protocol: Set the protocol to be used on the Editor port.
Editor Port Setting: Make settings relating to the control of the four editor
ports installed in the DME.
GPI Input: Set the GPI input ports and trigger polarities, and make the
action settings.
GPI Output: Set the GPI output ports and trigger polarities, and make the
action settings.
Setup Relating to DCU Input/Output
In DCU setup, carry out settings particular to the DCU.
You can make the following settings.
Input Config: Assign GPI inputs to Parallel input ports.
GPI Input Assign: Make GPI input settings.
Output Config: Assign GPI outputs to parallel output ports inserted in an
option slot.
GPI Output Assign: Make GPI output settings.
Serial Port Assign: Set the protocol to match the devices connected to a 9-
pin serial port. You can also select the control panel used to control each
device.