Sony MVS8000 Switch User Manual


 
499Still Image Operations
Chapter 7 Frame Memory
To return the settings to the default values, press [Unity] in the <Video
Process> group.
Note
When a pair setting is active, it is coupled to the video process on/off
setting, but the above parameter settings are only valid for frame memory
source bus 1. The pair setting cannot be used to set the frame memory
source bus 2. If you want to set video process for frame memory source bus
1 only with the pair setting when old settings for frame memory source bus
2 remain, return the frame memory source bus 2 settings to their default
values. When setting video process for the frame memory source bus 2,
disable the pair setting.
Setting a mask
Masks can be set separately for frame memory source buses 1 and 2. To apply
a mask to the signal selected on frame memory source bus 1, for example, use
the following procedure in the Still >Freeze/Store menu.
1
Press [Box Mask] turning it on.
2
Use the knobs to adjust the following parameters.
3
To link the masks on frame memory source buses 1 and 2, press [Mask
Link], turning it on.
Knob Parameter Adjustment Setting values
1 Video Gain Overall gain of the video signal –200.00 to +200.00
2 Y Gain Y signal gain –200.00 to +200.00
3 C Gain Chrominance signal gain –200.00 to +200.00
4 Hue Delay Hue delay –180.00 to +180.00
5 Black Level Y signal black level –7.31 to +109.59
Knob Parameter Adjustment Setting values
1 Top Top position –100.00 to +100.00
2 Left Left position –100.00 to +100.00
3 Right Right position –100.00 to +100.00
4 Bottom Bottom position –100.00 to +100.00