Sony MVS8000 Switch User Manual


 
243Multi Program 2
Chapter 1 MVS-8000 Functions
a) Keys 2 to 4 are common to main and sub.
Notes
Allow a transition to complete before carrying out main and sub delegation
switching.
The sub background A bus (utility 2 bus) is shared with wipe edge border fill.
Making a change to one affects the other.
Even if the wipe border width is set to the same numeric value for main and
sub, the same image is not obtained.
Changing the position of the wipe pattern for sub also changes the pattern
size.
Restrictions on Using Multi Program 2 Mode
The following functions are not available for sub:
Data copy and swap
Default recall (except for parametric recall)
–M/E link
[TRANS] button function (see page 268)
[TRACE] button function (see page 270)
[AUTO] button function (see page 309)
Re-entry is limited to four levels. Re-entry is not possible for main and sub
of the same M/E.
However, this restriction can be removed. For details, see “Enabling re-
entry between the main and sub sides of the same M/E bank” (page 240).
In the following cases, a transition using the fader lever may not be
performed correctly:
When the main and sub bus toggle modes are set differently
For a pattern mix, preset color mix, and so on
For an Internal bus link, GPI link, or External bus link, the “Utility 2” bus
cannot be selected.
Screen aspect, show key, and [MCRO ATTCH ENBL] button settings are
common to main and sub.
If a snapshot is recalled simultaneously for main and sub, or a keyframe is
executed simultaneously for main and sub, then for the following common
to main and sub the main settings are reflected.
–Key
–M/E Config
DME external video bus and utility 1 bus
Operation setting for
switcher GPI inputs and
outputs
Same as standard mode Cannot be used
Item Main Sub