234
Multi Program 2
Chapter 1 MVS-8000 Functions
• OUT1, OUT2: main only
• OUT3, OUT4: can be used for either main or sub
• OUT5, OUT6: sub only
For details, see “To assign the output of each bank in Multi Program mode”
in Chapter 16 (Volume 2).
To set the background and key configuration
Use the Engineering Setup >Switcher >Config >PGM Config menu.
The following are the differences from standard mode.
Background configuration: Consists of the following combinations.
• For main: Clean, Bkgd A, Bkgd B
• For sub: Sub Clean, Utility 2, Utility 3
Key configuration: Key1 can be set to “Enable” only when the background is
Clean, Bkgd A, or Bkgd B.
For details, see “To set the output configuration for each bank” in Chapter 16
(Volume 2).
To set the key preview configuration
Use the Engineering Setup >Switcher >Config >K-PVW Config menu.
The following are the differences from standard mode.
Background configuration: Clean or Sub Clean
Key configuration: Key1 can be set to “On” or “Link” only when the
background is Clean.
For details, see “To set the key preview configuration” in Chapter 16 (Volume
2).
To assign sub outputs to output ports
Use the Engineering Setup >Switcher >Output >Output Assign menu.
You can assign a sub output signal to a switcher output port number.
For details, see “Assigning output signals” in Chapter 16 (Volume 2).
Assigning main and/or sub to switcher banks
For each switcher bank for which Multi Program 2 mode is selected, set
whether this is main dedicated, sub dedicated, or main and sub shared.
To assign main and sub to a single switcher bank
1
In the Engineering Setup >Panel >Config >MP2 Main/Sub Assign menu,
select the switcher bank.
2
In the <Main/Sub Assign> group, select [Main&Sub].
Main: use for main operations.