Sony MVS8000 Switch User Manual


 
32
Signal Selection
Chapter 1 MVS-8000 Functions
Note
This setting is cleared when you reset the control panel.
Assigning a button to the function of disabling cross-point button
operation
You can assign the button to be used for the operation to the [PRE MCRO]
button, in setup. (See Chapter 16, “Overall Control Panel Settings (Config
Menu)” (Volume 2))
You can also use the [Inhibit Set] and [Inhibit All Clear] functions, assigned to
user preference buttons. (See Chapter 16, “Setting Button Assignments (Prefs/
Utility Menu)” (Volume 2))
Buses for which operations can be inhibited
This setting applies to the AUX control block and switcher bank cross-point
buttons.
For example, if you make the setting for one cross-point button in a switcher
bank, this inhibits operation of all cross-point buttons with the same number in
the following buses.
The corresponding name also disappears from the source name display.
Background A, background B
•Keys 1 to 4
Utility 1, utility 2
DME utility 1, DME utility 2
External DME
To inhibit operation of a cross-point button
Hold down the button which “Inhibit Set” is assigned, and press the cross-point
button whose operation you want to inhibit.
The button you pressed flashes amber, and this makes the operation inhibited.
Note
Even when you inhibit operation of a cross-point button, macro attachment
settings are still possible (see page 218).
To clear a cross-point button operation inhibit setting
Hold down the button to which “Inhibit Set” is assigned, and press the button
whose operation is inhibited (flashing amber).
This clears the operation inhibit setting for the button you pressed.
To clear all operation inhibit settings
Press the button to which “Inhibit Set” is assigned and the button to which
“Inhibit All Clear” is assigned simultaneously.