Working with public access attributes
Attribute definitions
Access request
Acct-Session-Id
(32-bit unsigned integer)
Random value generated per authentication by the service controller.
Called-Station-Id
(string)
By default, this is set to the MAC address of the service controller wireless/LAN port in IEEE
format. For example: 00-02-03-5E-32-1A. To use the MAC address of the Internet port, you
must edit the config file and change the setting of radius-called-station-id-port to WAN in
the <ACCESS-CONTROLLER> section.
Calling-Station-Id
(string)
The MAC address of the service controller LAN port in IEEE format. For example: 00-02-03-
5E-32-1A.
CHAP-Challenge
(string)
Randomly generated by the product. As defined in RFC 2865. Only present when the
authentication method for the RADIUS profile is set to CHAP. Length = 19 bytes.
CHAP-Password
(string)
The password assigned to the service controller on the Public access > Attributes page.
Encoded as defined in RFC 2865. Only present when the authentication method for the
RADIUS profile is set to CHAP.
Connect-Info
(string)
The string “HTTPS”.
EAP-Message
(string)
As defined in RFC 2869. Only present when the authentication method for the RADIUS profile
is set to EAP-MD5.
Framed-IP-Address
(32-bit unsigned integer)
IP Address of the service controller LAN port.
Framed-MTU
(32-bit unsigned integer)
Hard-coded to 1496 (802.1X). Hard-coded value of 1496. The value is always four bytes lower
than the wireless MTU maximum which is 1500 bytes in order to support IEEE802dot1x
authentication.