IBM 8260 Switch User Manual


 
Figure 70 shows the side view of the 20/40-port 10Base-T modules. As can be
seen, in addition to the 8 isolated segments and the mounting for two E-MACs,
there is an 8-position DIP switch located on the module. These DIP switches are
used in the absence of an installed management module in the 8260. However,
if a management module is installed in your 8260, the setting of these DIP
switches will be ignored. For more information, please refer to 4.2.4.4, “
Configuring DMM Device” on page 50.
Table 19 (Page 2 of 2). 20/40-Port 10Base-T Module LED Descriptions
LED Name Color State Description
Status Green On Port enabled and link OK
Off Port disabled.
1 Blink Link failure on the port
2 Blinks Port partitioned
Figure 70. 20/40-Port 10Base-T Module Side View
The expanded view of the DIP switches is shown in Figure 71 on page 110.
Chapter 7. 8260 Ethernet Modules 109