Hub Information:
Hub Type: 58G5801
Backplane Information:
Backplane Type Revision
-------------- --------
Load-Sharing Power Distribution Board 0
Enhanced TriChannel Backplane 0
Ring Backplane 0
Power Supply Information:
Power Supply Status Model Number
------------ ------ ------------
1 OKAY 6000PS
2 OKAY 6000PS
3 OKAY 6000PS
4 REMOVED
Temperature Information:
Probe Location Temperature
----- -------- -----------
1 FAN_1 27 Degrees Celsius
2 FAN_2 29 Degrees Celsius
3 FAN_3 27 Degrees Celsius
Fan Information:
Fan Status
--- ------
1 OKAY
2 OKAY
3 OKAY
8260>
Figure 46. Output from Show Hub Command
You can use the following management command to determine the amount of
power installed and the amount of power budget available in your hub:
SHOW POWER BUDGET
An example of the output from this command is shown in Figure 47 on page 78.
Chapter 5. 8260 Intelligent Power Management Subsystem 77