IBM 8260 Switch User Manual


 
Config * OSPF Static Default Convert TablModule: BladeRunner
System Page 1 Time: 17:49 11 Jan 95
TOS Hop Count Metric
01 10
02 20
03 30
04 40
05 50
06 60
07 70
08 80
09 90
0 10 100
Modify Entry Prev Page Next Page Exit
Return to the previous screen
Figure 182. LMS OSPF Default Static Convert Table Panel
The following parameters can be viewed/modified for each entry:
Hop Count
This parameter specifies hop count measured in RIP.
Metric
This parameter specifies the metric in OSPF converted from RIP.
15. You may define filtering information for IP packets as described in 11.8.9, “IP
Security.”
11.8.9 IP Security
IP security feature of the Multiprotocol Interconnect module allows you to define
filters which are used to determine which IP packets are forwarded and which
ones are discarded when the Multiprotocol Interconnect module is performing IP
routing functions.
The IP security feature is comprised of up to 31 different
Security Tables
and a
Security Access List
. Each security table can contain up to 64 address entries
and is identified by a
list no
.
To use IP security, you must do the following:
1. Create one or more
IP security tables
to define the filtering information
against which the incoming packets may be checked. To do so, you must
select
IP Security Table
from the
IP Menu
. An example of an IP security
table is shown in Figure 183 on page 305.
304 8260 Multiprotocol Intelligent Switching Hub