IBM 8260 Switch User Manual


 
8260A>
8260A> show module 8.2 verbose
Slot Module Version Network General Information
----- --------------- ------- ------------- -------------------
08.02 T-MAC v2.00 TOKEN_RING_7
T-MAC: Token Ring Network Monitor Card
Boot Version: v2.00
IP Address: 9.67.46.195
Subnetwork Mask: ff.ff.ff.f0
Default Gateway: 0.0.0.0
Station Address: 10-00-f1-0b-58-00
Locally Administered Address: 00-00-00-00-00-00
MAC Address Type: BURNED-IN
Interface Mode: ENABLED
RMON Groups: ENABLED
Surrogate Groups: DISABLED
Dot5 Group: DISABLED
RMON Host Statistics Collection: ENABLED
RMON MAC Layer Statistics Collection: ENABLED
RMON Promiscuous Statistics Collection: ENABLED
RMON Ring Station Statistics Collection: ENABLED
RMON Source Routing Statistics Collection: ENABLED
Monitor Contention: DISABLED
Adapter Status: OPENED
Adapter Microcode Version: 00 00 01 c1 e3 f1 f7 c3 f1 40
Early Token Release: DISABLED
Internal Wrap: DISABLED
External Wrap: DISABLED
Interface Number: 6
8260A>
Figure 132. Show Module Command for T-MAC
As can be seen, at the time of display, all the RMON groups are enabled on
the T-MAC.
6. Once the T-MAC is enabled to collect the appropriate RMON group, you can
display the collected information using the following command:
SHOW COUNTER RMON {rmon group} {network}
This command is described in 10.6.5, “SHOW COUNTER Command for
Token-Ring Networks” on page 222.
10.7 Surrogate Functions Supported by T-MAC
The token-ring architecture defines the Configuration Report Server (CRS) and
Ring Error Monitor (REM) functions.
The Ring Error Monitor (REM) observes, collects, and analyzes hard-errors and
soft-error reports sent by the ring stations on a single ring and assists in fault
isolation and correction. Configuration Report Server (CRS) function accepts
commands from the LAN manager to get station information, set station
232 8260 Multiprotocol Intelligent Switching Hub