IBM 8260 Switch User Manual


 
Filter Test Table
. Note that there is only one of these tables in each
Multiprotocol Interconnect module and it contains all the test that are to be
performed by the Multiprotocol Interconnect module, regardless of the ports
on which these tests are performed.
To define the tests, select
Custom Filter Test Table
from the
Bridge Menu
.
An example of the panel displayed is shown in Figure 158.
Config * Custom Filter Test Table Module: BladeRunner
System Page 1 Time: 14:07 9 Jan 95
ID Test Name Filter Start Offset Mask Operator Value
1 ″″ mac 0 00000000 equal 00000000
2 ″″ mac 0 00000000 equal 00000000
3 ″″ mac 0 00000000 equal 00000000
4 ″″ mac 0 00000000 equal 00000000
5 ″″ mac 0 00000000 equal 00000000
6 ″″ mac 0 00000000 equal 00000000
7 ″″ mac 0 00000000 equal 00000000
8 ″″ mac 0 00000000 equal 00000000
9 ″″ mac 0 00000000 equal 00000000
10 ″″ mac 0 00000000 equal 00000000
11 ″″ mac 0 00000000 equal 00000000
12 ″″ mac 0 00000000 equal 00000000
Modify Entry Prev Page Next Page Exit
Return to the previous screen
Figure 158. LMS Custom Filter Test Table Panel
This table may have up to 64 entries. You may define the following
parameters for each entry:
ID Number
This number is used to refer to this test from the other filtering tables.
Test Name
:
This is a meaningful name assigned to the test and used to refer to this
test from the other filtering tables.
Filter Start Point
This field is used to select either MAC header, LLC header or length of
the frame as the starting point for the offset into the frame.
Offset
This field represents the number of bytes from the
Filter Start Point
within the frame where the test is to apply. The test can start anywhere
within the first 65,536 bytes of a frame.
Note: When frame_length is specified as the filter start point, the offset
is not applied.
Mask
Chapter 11. 8260 Multiprotocol Interconnect Module 275