By default, the module is shipped from the factory with the DIP switches set
for Ethernet_1.
•
Use DIP switch position 5 to choose if the module is going to use the
Non-Volatile RAM (ON position) or DIP switch settings (OFF position) for its
configuration. Note that if there is a management module installed in the
8260, this DIP switch determines which configuration (NVRAM or DIP switch
setting) will be sent to the management module. The actions taken by the
management module, upon receipt of this information are described in
4.2.4.4, “ Configuring DMM Device” on page 50. By default, the DIP switch 5
is set to NVRAM.
7.8 10Base-FB Module Usage
Figure 75 provides an example of the usage of the 8260 Ethernet 10-Port
10Base-FB Module.
Figure 75. 10-Port 10Base-FB Module Usage
7.9 Configuring the 10Base-FB Module
To configure the 8260 Ethernet 10-Port 10Base-FB Module you must do the
following:
•
Select a network for each port
Each port can be assigned to one of the 8 Ethernet segments on the
backplane or one of the 4 isolated segments on the module.
The port assignment can be done via onboard dip switches or the following
management module command:
SET PORT {slot.port} NETWORK {network}
118 8260 Multiprotocol Intelligent Switching Hub