MGC Manager User’s Guide - VoicePlus Edition
6-7
noisy line. At this point, the muted participant can press <9> to listen to a
menu which lists the following options:
• Return to the conference unmuted (default)
• Return to the conference muted
• Reduce the level of the SilenceIT Sensitivity and return to the conference
unmuted
• Disable the SilenceIT feature for this conference and return to the
conference unmuted
For IVR messages used with SilenceIT, see Table 6-10 on page 6-33.
• SilenceIT is supported for Audio Only participants in IVR-enabled
Audio and Video conferences.
• SilenceIT is not supported when the participant is moved to the Operator
Conference (Attended status).
• SilenceIT is not supported in Recording Ports and with DTMF
Forwarding.
• SilenceIT is not applicable with Cascading conferences.
Enabling SilenceIT
Enabling the SilenceIT option for an IVR Service is described on page 6-16.
The SilenceIT option is enabled for conferences by assigning a SilenceIT-
enabled IVR Service and by selecting his option in the Conference
Properties - Settings dialog box. However, if the option is not enabled in the
IVR Message Service, it cannot be activated for the conference. If you enable
this option while an IVR Service you selected as the Message Service type is
not SilenceIT-enabled, the conference definition will be rejected.