Dell IDRAC6 Laptop User Manual


 
320 Monitoring and Alert Management
3
Configure your PET policy.
At the command prompt, type the following command
and press <Enter>:
iPv4:racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertDestIPAddr -i 1
<IPv4_address>
iPv6:racadm config -g cfgIpmiPetIpv6 -o
cfgIpmiPetIPv6AlertDestIPAddr -i 1
<IPv6_address>
where
1
is the PET destination index and
<IPv4_address>
and
<IPv6_address>
are the destination IP addresses of the system that
receives the platform event alerts.
4
Configure the Community Name string.
At the command prompt, type:
racadm config -g cfgIpmiLan -o
cfgIpmiPetCommunityName
<Name>
Configuring E-Mail Alerts
Configuring E-mail Alerts Using the Web User Interface
For detailed information, see "Configuring E-Mail Alerts" on page 60.
Configuring E-Mail Alerts Using the RACADM CLI
1
Enable your global alerts.
Open a command prompt, type the following command,
and press <Enter>:
racadm config -g cfgIpmiLan -o
cfgIpmiLanAlertEnable 1
2
Enable e-mail alerts.
At the command prompt, type the following commands and
press <Enter> after each command:
racadm config -g cfgEmailAlert -o
cfgEmailAlertEnable -i 1 1