Dell IDRAC6 Laptop User Manual


 
Configuring the iDRAC6 Using the Web Interface 85
Using iDRAC you can view the status, health, and availability of IDSDM.
The SD card redundancy status and failure events are logged to SEL,
displayed on LCD, and PET alerts are generated if alerts are enabled.
Viewing Internal Dual SD Module Status Using GUI
1
Log in to the iDRAC Web GUI.
2
Click
Removable Flash Media
. The
Removable vFlash Media
page is
displayed. This page displays the following two sections:
Internal Dual SD Module
— Displayed only if IDSDM is in redundant
mode.
The Redundancy Status is displayed as Full. If this section is not
present, then the card is in the non-redundant mode state. The valid
Redundancy Status indications are:
Full
— SD card 1 and 2 are functioning properly.
Lost
— Either one of the SD card or both the SD cards are not
functioning properly.
Internal SD Module Status
— Displays the SD card state for SD1, SD2,
and vFlash cards with the following information:
Status:
— Indicates that the card is ok.
— Indicates that the card is offline or write-protected.
— Indicates that an alert is issued.
Location — Location of the SD cards.
Online Status — SD1, SD2, and vFlash cards can be in one of the
states listed in Table 4-32.
Table 4-31. IDSDM Status
IDSDM - Mirror
Mode
SD1 Card SD2 Card vFlash SD Card
Enabled Active Active Inactive
Disabled Active Inactive Active