This screen is also displayed when F7 is selected and the previous resource is a
remote HSL NIC and when F8 is selected and the next resource is a remote HSL
NIC.
The following fields appear on the Display HSL Information displays:
HSL loop number: The HSL loop number is the numerical value of the HSL loop
to which the resource belongs.
HSL resource information: The next several fields display detailed information
about the resource:
Type-model
This field contains the type and model numbers as reported by the
hardware.
Status This field indicates the current status of the logical resources as reported
by the hardware. The list below states the possible values for this field:
Unknown
The system cannot determine status. The resource may be
non-reporting or unable to communicate status.
Operational
The resource is functioning normally. For HSL loops, this also
means that all links are connected and all resources are operational.
Not operational
This system does not own or control this resource.
Failed The resource has failed or been powered off for concurrent
maintenance.
Serial number: This field represents the serial number of the logical hardware
resource.
Display HSL Information
HSL loop number.........: 257
HSL I/O bridge resource
Type-model ...: 1999-999 Status ....:Operational
Serial number..: 21-1111111 Part number..:111111111111
Resource name..: BC06
Leading port to next resource..............:
Link status....: Operational Link type...: Copper
Type of connection .: Internal Link type...: 500
Trailing port from previous resource ..........:
Link status....: Operational Link type...: Copper
Type of connection .: Internal Link type...: 500
F3=Exit F6=Print F7=Follow trailing port F8=Follow leading port
F9=Include non-reporting resources F11=Display system information F12=Cancel
Figure 35. Example Display High Speed Link (HSL) Information display
Chapter 2. Hardware Service Manager 87