IBM SY44-5902-05 Server User Manual


 
Table 27. Function 01 on systems with a keystick
Function/data Action or description
01______________
________________
Use the Increment or Decrement buttons to
scroll to function 01.
01__A_____V=F___
________________
Valid IPL types are A, B, C, and D.
Valid IPL speed displays are F, S, SE, V=F,
or V=S.
01______________
________________
Use the Increment or Decrement buttons to
scroll through the control panel functions.
Function 01Display Selected IPL Type, Logical Key Mode, and IPL Speed (on
Systems without a Keystick): This function allows you to display the selected
IPL type, logical key mode, and speed for the next IPL.
1. Display IPL types (A, B, C, or D).
2. Display the valid logical key modes (M or N).
3. Display IPL speed (F, S, SE, V=F, or V=S).
Table 28 shows a function 01 example on systems without a keystick.
Table 28. Function 01 on systems without a keystick
Function/data Action or description
01______________
________________
Use the Increment or Decrement buttons to
scroll to function 01.
01__A__M__V=F___
________________
Valid IPL types are A, B, C, and D.
Valid logical key modes are M and N.
Valid IPL speed displays are F, S, SE, V=F,
or V=S
01______________
________________
Use the Increment or Decrement buttons to
scroll through the control panel functions.
Function 02Select IPL Type and IPL Speed Override (on Systems with a
Keystick): Before you can use function 02, you must have the system in Manual
mode. Selection changes to IPL types can be done with the system powered on or
off. Before you can select the IPL speed override, the system must be powered off.
Table 29 shows the sequence of selecting the IPL type on iSeries servers that are
powered on.
Table 29. Function 02 select IPL type on powered-on systems with a keystick
Function/data Action or description
02______________
________________
Use the Increment or Decrement buttons to
scroll to function 02.
02__A<__________
________________
Press Enter to start function 02. The current IPL
type is displayed with a pointer.
02__B<__________
________________
Use the Increment or Decrement buttons to
scroll through the IPL types.
178 Service Functions V5R2