Table 23. Function 06 Disable CPM (continued)
Function / value Action or description
06___D__ Use the Increment or Decrement buttons to display option D
(Disable).
06____00 Press Enter to perform the Disable CPM operation. With the 00
displayed the operation was successful (the SPCN interface is
operational and the Disable message will be sent). At the next IPL,
CPM is automatically available. If FF appears instead of 00,
function 06 failed due to an SPCN communications error.
Function 07–Restore System Power and Perform Concurrent Maintenance
Repair: Function 07 is available only on systems with SPCN and only when the
system is powered on and in Manual mode. Function 07 allows you to restore
power to frames that had a power failure or were powered off. It is also used for
concurrent maintenance repair on bulks and fans.
When you first enter function 07, the control panel enters subfunction mode by
displaying (**). Increment and decrement functions scroll to selectable values. If an
SPCN communications error is present when you select a subfunction, the
subfunction does not start, and FF (processing failed) displays in the rightmost
display positions. Entry of a valid subfunction when no SPCN communications
errors are present results in a 00 (processing successful) displayed in the rightmost
display positions. Pressing Enter when ** is displayed results in exiting
subfunction mode. For example:
Table 24. Function 07 Restore System Power and Perform Concurrent Maintenance Repair
Function / data Action or description
07______ Use the Increment or Decrement buttons to scroll to function 07.
07**____ Press Enter to enter function 07 subfunction mode.
0704____ Use the Increment or Decrement buttons and scroll to desired
subfunction (04 in this example). Valid subfunctions are 01, 02, 03,
04, and 05.
0704__00
briefly, then
07**____
Press Enter to execute subfunction 04. An SPCN communications
error was not present, resulting in 00. If an error occurs, FF
displays.
07F3__00 Use the Increment or Decrement buttons to select a specific device
(in this case F0 - F3).
0704__00
briefly, then
07**____
Press Enter to exit the subfunction for the specified device and exit
to the subfunction level.
See the following list for valid subfunction values and their meanings.
** Cancel Request
The system returns this subfunction when you select ** for subfunction and
activate enter. Use this to cancel a pending subfunction 2–5 concurrent
maintenance operation. SPCN responds with an EPF 1–5 (enable panel
subfunction) to clear any other subfunction range enabled previously.
01 System Power On
Chapter 5. Control Panel Functions 167