IBM SY44-5902-05 Server User Manual


 
C200 7xxx
Secondary Partition Load Source Device Disconnection Phase
C200 7100
Disconnecting from load source device
C200 7110
Preparing to remove the load source IOP from the primary partition
C200 7120
Load source IOP has been successfully removed from the primary partition
C200 71FF
Load source is successfully disconnected
C200 8xxx
Secondary Partition Start Processors Phase
C200 8100
Initializing SP Communication Area #2
C200 8104
Loading data structures into mainstore
C200 8110
Initializing event paths
C200 8120
Starting processors
C200 81FF
Processors started successfully, now waiting to receive the continue
acknowledgment from SLIC
C200 8200
Continue acknowledgment received from SLIC
C200 82FF
VSP IPL complete successfully
C3xx xxxx
System Processor or Main Storage Diagnostic in progress
C5xx xxxx
LIC system hardware initialization
C500 C92B
Waiting for console device - error condition only if console not found
C6xx 1800
LIC SPCN setup
C600 3900
SP transfer control of Bus 1 (BCU Switch) to LIC is Complete and LIC
Machine Facilities component is initialized
C600 3910
LIC has initiated PCI Bus Reset to all Bus 1 devices except the SP
C600 3911
LIC has initiated self test of all Bus 1 devices except the SP
C600 3912
LIC is initiating IPL of the Load Source IOP
Chapter 6. System Reference Code (SRC) Information 205