IBM SY44-5902-05 Server User Manual


 
Table 9 on page 117 is generally reserved for engineering use. However, to get
additional information for IOP product activity log entries at DST when using a
D-IPL (which begins at offset hex 000180), see More information from
hexadecimal reportson page 117.
Table 7. Hexadecimal dump byte assignments for keyed data
Hexadecimal offset Length in bytes Description
0000 4 Internal release level
0004 4 Length of component specific data
0008 2 Non-keyed data start @
000A 2 Component specific start @
000C 8 Time stamp
0014 4 Sequence number
0018 1 Subsystem type
0019 1 Analysis done
001A 4 System log ID
001E 2 Reserved
0020 2 Reference code
0022 2 Reserved
0024 1 Class
0025 1 Reserved
0026 8 SRID
002E 2 Reserved
0030 4 Device type
0034 4 Model number
0038 10 Serial number
0042 4 IOP type
0046 4 I/O adapter type
004A 10 I/O processor direct select address
2 Transport type
2 Bus
2 Board
2 Card
2 Reserved
0054 12 Unit address
0060 4 Reserved
0064 6 Power address
006A 2 Reserved
006C 5 Card position
0071 5 Device position
0076 10 Reserved
0080 10 Network interface name
008A 10 Line name
0094 10 Controller description
009E 10 Device description
00A8 15 Reserved
00B7 1 Overlay flag
00B8 40 Volume ID/JOB information
Table 8. Hexadecimal dump byte assignments for non-keyed data
Hexadecimal offset Length in bytes Description
00E0 8 Reference code translate table (RCTT) name
00E8 2 Reserved
00EA 4 Product ID
116 Service Functions V5R2