Last battery capacity test date
This field gives the date of the last battery test in the format MM/DD/YY.
Last battery capacity test time
This field gives the time of the last battery test in the format HH:MM:SS.
Next battery capacity test date
This field gives the date of the next battery test in the format MM/DD/YY.
Next battery capacity test time
This field gives the time of the next battery test in the format HH:MM:SS.
Power sequence complete
This field indicates whether or not the power sequence is complete. Field values
are Yes or No.
Fault
This field indicates whether or not a power or functional fault currently exists.
Field values are Yes or No.
Note: The Display status of regulators function key (F6) on the Display Detail for
Unit display is not recommended for service representative use.
Display trace log
If you select option 6 (Display trace log) on the System Power Control Network
(SPCN) display, the following display appears. It shows the trace log data in both
hexadecimal and EBCDIC formats. A message appears at the bottom of the display
to indicate (as a hexadecimal number of bytes) the amount of data that is returned
. You can page up and down to see the entire trace log.
Note: It might take minutes to retrieve all the data; how long depends on the size
of the trace log.
The Display Data display shows a section of data from the system. The leftmost
column indicates the offset of this data line from the beginning of the data buffer
that is being displayed. The next 4 columns display four, 4-byte hexadecimal
numbers that begin at that offset. The last column displays the EBCDIC equivalent
of these 16 bytes. Non-displayable characters (characters not part of the National
Display Data
Data
Offset -------------Hexadecimal-------------- -----EBCDIC-----
0000 00000000 10FFD007 070010FF 04010000 ................
0010 11020400 00001105 0100D537 00000404 ..........N.....
0020 00C00000 0405000F 00000101 0703000C ................
0030 01030000 000C0402 0014000C 04020015 ................
0040 00000000 000C0104 00000022 0604931F ................
0050 00220613 00120032 06060000 003D0603 ................
0060 00000683 06100300 06850504 00010692 ................
0070 06049A20 06920613 000006A2 06060000 ................
0080 00000000 06AD0603 000006AF 061A0600 ................
0090 06AF060A FFFF0B9D 06118521 0B9D060D ................
00A0 04EC0B9D 060E0597 00030204 0000000C ................
00B0 02060000 000C0209 0000000C 020C0000 ................
00C0 00000000 000E0403 0014000E 04030015 ................
00D0 00280100 D5370000 040400C0 00000405 ....N...........
00E0 000F0000 01010703 000C0103 0000000C ................
More...
F3=Exit F12=Cancel
00000640 (hex) bytes of data returned. Retrieve trace log buffer successful.