For PowerPC-based IOPs, you set all four bytes of the address (wwxx yyzz). Set ww
with the first use of function 59. Set xx with the second use of function 59. Set the
yy with Function 60 and zz with Function 61 as described in Changing the
address.
Changing the address
For PowerPC-based IOPs: Setting the ww Position:
1. Press the Increment () or Decrement () switch until 59 appears in the
Function display.
2. Press Enter on the control panel; ** appears next to the function number.
3. Press the Increment () or Decrement () switch until the value of ww appears
next to the function number.
4. Press Enter on the control panel.
5. Press the Increment () or Decrement () switch until ** appears next to the
function number (59**).
6. Press Enter on the control panel.
To continue, follow the steps in For Motorola** 68020 Processor-based IOPs
below.
For Motorola** 68020 Processor-based IOPs: Setting the xx Position:
1. Press the Increment () or Decrement () switch until 59 appears in the
Function display.
2. Press Enter on the control panel; ** appears next to the function number.
3. Press the Increment () or Decrement () switch until the value of xx appears
next to the function number.
4. Press Enter on the control panel.
5. Press the Increment () or Decrement () switch until ** appears next to the
function number (59**).
6. Press Enter on the control panel.
Setting the yy Position:
7. Press the Increment () or Decrement () switch until 60 appears in the
Function display.
8. Press Enter on the control panel; ** appears next to the function number.
9. Press the Increment () or Decrement () switch until the value of yy appears
next to the function number.
10. Press Enter on the control panel.
11. Press the Increment () or Decrement () switch until ** appears next to the
function number (60**).
12. Press Enter on the control panel.
Setting the zz Position:
13. Press the Increment () or Decrement () switch until 61 appears in the
Function display.
14. Press Enter on the control panel; ** appears next to the function number.
15. Press the Increment () or Decrement () switch until the value of zz appears
next to the function number.
16. Press Enter on the control panel. Record the data from the display as the base
address.
134 Service Functions V5R2