IBM SY44-5902-05 Server User Manual


 
17. Press the Increment () or Decrement () switch until ** appears next to the
function number (61**).
18. Press Enter on the control panel.
You just entered your address into the system. Now use the Displaying data from
function 62on page 136 procedure to obtain the information from function 62.
Changing the address in functions 58 through 61 (Models 270,
8xx, SB2, SB3, and 890)
Introduction
For this procedure, use the address you were given when you were sent to this
procedure. The address consists of 4 bytes.
The ww, xx, yy, and zz represent parts of the address.
Set all 4 bytes of the address (wwxx yyzz) as described in Changing the address.
v Set the ww with function 58.
v Set the xx with function 59.
v Set the yy with Function 60.
v Set the zz with Function 61.
Changing the address
Setting the ww Position:
1. Press the Increment () or Decrement () switch until 58 appears in the
Function display.
2. Press Enter on the control panel; ** appears next to the function number.
3. Press the Increment () or Decrement () switch until the value of ww appears
next to the function number.
4. Press Enter on the control panel.
5. Press the Increment () or Decrement () switch until ** appears next to the
function number (58**).
6. Press Enter on the control panel.
Setting the xx Position
1. Press the Increment () or Decrement () buttons until 59 appears in the
Function display.
2. Press Enter on the control panel; ** appears next to the function number.
3. Press the Increment () or Decrement () buttons until the value of xx appears
next to the function number.
4. Press Enter on the control panel.
5. Press the Increment () or Decrement () buttons until ** appears next to the
function number (59**).
6. Press Enter on the control panel.
Setting the yy Position
1. Press the Increment () or Decrement () buttons until 60 appears in the
Function display.
2. Press Enter on the control panel; ** appears next to the function number.
Chapter 4. Service Reference Procedures 135