NETGEAR GS700TR Switch User Manual


 
GS700TR Smart Switch Software Administration Manual
Configuring Switching Information 3-51
v1.0, May, 2008
Interface: Select Interface from the menu, enter the interface ID in g1, g2... format. Then
click Go. If any entries with learned on that interface exist, they are displayed.
Figure 3-35
Table 3-33. MAC Address Table Fields
Field Description
VLAN ID Specifies the VLAN ID on which the IGMP Snooping Querier is
administratively enabled and for which VLAN exists in the VLAN
database.
MAC Address A unicast MAC address for which the switch has forwarding and/or
filtering information. The format is a six byte MAC address with each
byte separated by colons. For example: 00:0F:89:AB:CD:EF.
Interface The port where this address was learned. In other words, this field
shows the port through which the MAC address can be reached.
Status The status of this entry. The possible values are:
Static: The entry was added when a static MAC filter was defined.
Learned: The entry was learned by observing the source MAC
addresses of incoming traffic, and is currently in use.
Management: The system MAC address, which is identified with
interface c1.