ADC10 Operation
18-10
ADC10
Single-Channel Single-Conversion Mode
A single channel selected by INCHx is sampled and converted once. The ADC
result is written to ADC10MEM. Figure 18−5 shows the flow of the
single-channel, single-conversion mode. When ADC10SC triggers a
conversion, successive conversions can be triggered by the ADC10SC bit.
When any other trigger source is used, ENC must be toggled between each
conversion.
Figure 18−5. Single-Channel Single-Conversion Mode
ADC10
Off
x = INCHx
Wait for Enable
ENC =
Wait for Trigger
Sample, Input
Channel
ENC =
ENC =
SHS = 0
and
ENC = 1 or
and
ADC10SC =
SAMPCON =
Convert
ENC = 0
ENC = 0
†
12 x ADC10CLK
Conversion
Completed,
Result to
ADC10MEM,
ADC10IFG is Set
1 x ADC10CLK
†
Conversion result is unpredictable
ENC = 0
†
ADC10ON = 1
CONSEQx = 00
(4/8/16/64) x ADC10CLK
x = input channel Ax