Command Dictionary Report Aborted Faults
FastScan and FlexTest Reference Manual, V8.6_4
2-259
Report Aborted Faults
Tools Supported: FastScan and FlexTest
Scope: Atpg, Good, and Fault modes
Usage
REPort ABorted Faults [format_type]
Description
Displays information on undetected faults caused when the tool aborted the
simulation during the ATPG process.
The Report Aborted Faults command can help you determine why faults in the
undetected fault list were aborted. You can then analyze whether to change the
current abort limit to possibly allow those faults to complete the ATPG process
before the simulation aborts them. To change the abort limit, use the Set Abort
Limit command.
Arguments
• format_type
An optional literal that specifies the type of information that you want the tool
to display regarding the aborted faults. The literal choices for the format_type
argument are as follows:
Summary — A literal that displays a summary of the number of aborted
faults for each category. This is the default.
All — A literal that displays all the aborted faults that are currently in the
undetected fault list.
Backtrack — A literal that displays all the aborted undetected faults that
exceeded the backtrack limit.
Clock_restriction — (FastScan Only) A literal that displays all the aborted
undetected faults that had multiple clocks turned on.
Cycle — (FlexTest Only) A literal that displays all the aborted undetected
faults that exceeded the cycle limit