FastScan and FlexTest Reference Manual, V8.6_4
2-316
Report Gates Command Dictionary
The following describes the fields for the write port message line:
write port: write=G/G (vvv-v-v) first_adr=G first_di=G stability=vv
Identifies the behavior of the
write clock and write enable
lines for a given write port:
G/G Two gate index numbers separated by a “/”.
First G is the write clock line.
Second G is the write enable line. A “-”means there is no enable line.
(vvv-v-v) Up to five values indicating the behavior of the following conditions,
respectively:
clock_off_enable_off
clock_on_enable_off (Not shown if there is no enable line.)
clock_off_enable_on (Not shown if there is no enable line.)
two optional clock information values separated by dashes (-)
The first three values can be any of the following:
X (write X)
0 (write 0)
1 (write 1)
H (hold old values)
P (potential write)
The last two values can be either of the following:
CLK (write clock connected to scan clock)
IH (write clock line is inactive high)
Identifies the gate index number of the
first address line for a given write port.
In the list of gate inputs, the other
address inputs will immediately follow.
Identifies the gate index number of the
first data input line for a given write port.
In the list of gate inputs, the other
address inputs will immediately follow.
Identifies the following stability behavior
for a given write port, respectively:
write control stability
write load stability
The values can be either of the following:
S (stable)