NETGEAR GSM7228PS-100NAS Switch User Manual


 
Routing Commands
255
ProSafe Managed Switch
The following shows example CLI display output for the command.
(Switch) >show ip interface 1/0/2
Routing Interface Status....................... Down
Method......................................... None
Routing Mode................................... Disable
Administrative Mode............................ Enable
Forward Net Directed Broadcasts................ Disable
Proxy ARP...................................... Enable
Local Proxy ARP................................ Disable
Active State................................... Inactive
Link Speed Data Rate........................... Inactive
MAC address.................................... 02:14:6C:FF:00:DE
Encapsulation Type............................. Ethernet
IP MTU......................................... 1500
Bandwidth...................................... 100000 kbps
Destination Unreachables....................... Enabled
ICMP Redirects................................. Disabled
Method
Shows whether the IP address was configured manually or acquired from a DHCP
server.
Routing Mode
The administrative mode of router interface participation. The possible values are enable
or disable. This value is configurable.
Administrative
Mode
The administrative mode of the specified interface. The possible values of this field are
enable or disable. This value is configurable.
Forward Net
Directed
Broadcasts
Displays whether forwarding of network-directed broadcasts is enabled or disabled. This
value is configurable.
Proxy ARP
Displays whether Proxy ARP is enabled or disabled on the system.
Local Proxy
ARP
Displays whether Local Proxy ARP is enabled or disabled on the interface.
Active State
Displays whether the interface is active or inactive. An interface is considered active if its
link is up and it is in forwarding state.
Link Speed Data
Rate
An integer representing the physical link data rate of the specified interface. This is
measured in Megabits per second (Mbps).
MAC Address
The burned in physical address of the specified interface. The format is 6 two-digit
hexadecimal numbers that are separated by colons.
Encapsulation
Type
The encapsulation type for the specified interface. The types are: Ethernet or SNAP.
IP MTU
The maximum transmission unit (MTU) size of a frame, in bytes.
Bandwidth
Shows the bandwidth of the interface.
Destination
Unreachables
Displays whether ICMP Destination Unreachables may be sent (enabled or disabled).
ICMP Redirects
Displays whether ICMP Redirects may be sent (enabled or disabled).