Utility Commands
572
ProSafe Managed Switch
write memory
Use this command to save running configuration changes to NVRAM so that the changes
you make will persist across a reboot. This command is the same as copy
system:running config nvram:startup-config.
Format write memory
Mode
Simple Network Time Protocol (SNTP) Commands
This section describes the commands you use to automatically configure the system time
and date by using SNTP.
sntp broadcast client poll-interval
This command sets the poll interval for SNTP broadcast clients in seconds as a power of two
where <poll-interval> can be a value from 6 to 10.
Default
Format sntp broadcast client poll-interval <poll-interval>
Mode
no sntp broadcast client poll-interval
This command resets the poll interval for SNTP broadcast client back to the default value.
Format no sntp broadcast client poll-interval
Mode
sntp client mode
This command enables Simple Network Time Protocol (SNTP) client mode and may set the
mode to either broadcast or unicast.
Default
Format sntp client mode [broadcast | unicast]
Mode
Privileged EXEC
6
Global Config
Global Config
disabled
Global Config