Quality of Service (QoS) Commands
478
ProSafe Managed Switch
match srcl4port
This command adds to the specified class definition a match condition based on the source
layer 4 port of a packet using a single keyword or numeric notation. To specify the match
condition as a single keyword notation, the value for <portkey> is one of the supported port
name keywords (listed below). The currently supported <portkey> values are: domain,
echo, ftp, ftpdata, http, smtp, snmp, telnet, tftp, www. Each of these translates into its
equivalent port number, which is used as both the start and end of a port range.
To specify the match condition as a numeric value, one layer 4 port number is required. The
port number is an integer from 0 to 65535.
Default
Format match srcl4port {<portkey> | <0-65535>}
Mode
match vlan
This command adds to the specified class definition a match condition based on the value of
the layer 2 VLAN Identifier field (the 802.1Q tag of a VLAN tagged packet). The VLAN is an
integer from 0 to 4095.
Default
Format match vlan {<0-4095>}
Mode
match secondary-vlan
This command adds to the specified class definition a match condition based on the value of
the layer 2 secondary VLAN Identifier field (the 802.1Q tag of a double VLAN tagged packet).
The VLAN is an integer from 0 to 4095.
Default
Format match secondary-vlan {<0-4095>}
Mode
Format match srcip6 <source-ipv6-prefix/prefix-length>
Mode
Ipv6-Class-Map Config
none
Class-Map Config
Ipv6-Class-Map Config
none
Class-Map Config
Ipv6-Class-Map Config
none
Class-Map Config
Ipv6-Class-Map Config