3–116
OPERATIONS AND TIMING
COPYRIGHT
©
1998 CANON INC. CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
No.
324
325
326
327
328
Item
Duplex paper stack timing
adjustment
Set-back roller reversal timing
adjustment
Lamp intensity adjustment
Duplexing unit inlet arch adjustment
Duplexing unit out let adjustment
Settings
0 ~ 63
0 ~ 63
40 ~ 200
0 ~ 63
0 ~ 63
Description
A higher setting delays the ON timing.
unit: 0.27 mm
default: 32
A higher setting delays the reversal timing.
unit: 0.27 mm
default: 32
For factory only.
default: 125
A higher setting increases the arch.
default: 28
unit: 0.27 mm
A higher setting increases the arch.
default: 28
unit: 0.27 mm
Table 3-612-3