Logging And Network Management Command Set
Managing Switch Network Addresses and Routes
Matrix NSA Series Configuration Guide 11-113
Examples
This example shows how to display the MAC address timeout period:
This example shows how to display MAC address information for Fast Ethernet port 3 in port group
1:
Table 11-13 provides an explanation of the command output.
Matrix(rw)->show mac agetime
Aging time: 300 seconds
Matrix(rw)->show mac port-string fe.1.3
MAC Address FID Port Type Status
----------------- ---- ------------- ------- -------
00-01-F4-32-88-C5 0 fe.1.3 self
00-00-1D-12-11-88 3 fe.1.3 mgmt perm
Table 11-13 show mac Output Details
Output What It Displays...
MAC Address MAC addresses mapped to the port(s) shown.
FID Filter database identifier.
Port Port designation.
Type Address type. Valid types are:
• other - entry is other than below
• invalid - entry is no longer valid, but has not been yet
flushed-out
• learned - entry has been learned and is currently used
• self - entry represents one of the device's address
• mgmt - entry represents a dot1qStaticUnicastAddress
(manually entered MAC address)
• mcast - entry represents a dot1qStaticMulticastAddress
Status Address status. Valid types are:
• other - entry is other than below
• invalid - entry shall be removed
• perm - entry is currently in use and shall remain so
AFTER the next reset (permanent)