Fujitsu N1800 Scanner User Manual


 
475
z Carbonless paper contains chemical substances that may damage the pad assy or
the pick and other rollers when documents are fed. Pay attention to the following:
z cleaning
If pick errors occur frequently, clean the pad assy and pick roller.
For details about cleaning the pad assy and pick roller, refer to "Chapter 7
Scanner Care" (page 416).
z Replacing parts
The service life of the pad assy and pick roller may be shortened when
compared to scanning only wood containing paper documents.
z When wood containing paper manuscripts are scanned, the life of the pad assy and
pick roller may be shortened compared with the case where woodfree paper
manuscripts are scanned.
z When scanning photographs, the face of the photograph may become damaged.
z When scanning semi-transparent documents, set the scan [Brightness] to [Light] to
avoid image bleed through.
z To prevent the rollers from becoming dirty, avoid scanning documents containing
large areas written or filled in with pencil. If scanning of such documents is
unavoidable, clean the rollers frequently.
For details about cleaning the pad assy and pick roller, refer to "Chapter 7 Scanner
Care" (page 416).
z To operate correctly, the leading edges of all document sheets must be evenly
aligned. The curling of the leading edge must be within the following tolerances:
More than
30 mm
Feed direction
Side being
scanned
Leading edge
of document
Less than 3 mm
More than
30 mm
Feed direction
Side being
scanned
Leading edge
of document
Less than 5 mm