FC-210/310 TROUBLESHOOTING 4 - 52 February 2002 © TOSHIBA TEC
[Procedure 3]
Is the swing motor clock sensor (PI20) working normally?
NO
Replace the sensor.
YES
Does the voltage between J11-6 and -7 on the finisher controller PC board become 24V when the
swing motor starts rotating?
NO
Replace the finisher controller PC board.
YES
Is the wiring between the swing motor and finisher controller PC board correct?
NO
Correct the wiring.
YES
Replace the swing motor.
[CDA] Horizontal registration motor abnormal
Is the horizontal registration home position sensor (PI1P) working normally?
NO
Replace the sensor.
YES
Is the wiring between the horizontal registration home position sensor (PI1P) and finisher controller
PC board correct?
NO
Correct the wiring.
YES
Is the horizontal registration mechanism normal?
NO
Correct the mechanism.
YES
Is the problem solved by replacing the horizontal registration motor (M2P)?
YES
End
NO
Is the problem solved by replacing the punch driver PC board?
YES
End
NO
Replace the finisher controller PC board.