Toshiba FC-210 Copier User Manual


 
FC-210/310 ADJUSTMENT 2 - 14 February 2002 © TOSHIBA TEC
(c) Reproduction ratio adjustment of secondary-scanning direction (Fine adjustment of drum motor/transfer
belt motor rotation speed)
1. While pressing the digital keys [0] and [5] simultaneously, turn ON the power.(Adjustment mode)
2. Press [1][PRINTER/NETWORK]. (A grid pattern with 10mm squares is printed out. Use A3/LD from
the 2nd cassette.)
3. Measure the distance C between the 6th (down from the leading edge of the paper) and the 26th grid
lines of the grid pattern.
4. Check if the distance C is within 200±0.5 mm or not.
5. If it is not, use the following procedure to change values and repeat step 2. to 4. above.
<Procedure> (Adjustment mode)(Enter code [401] with digital keys)[START]
(Enter a value (acceptable values: 1608 to 1965) with digital keys)
[SET] or [INTERRUPT] (Stored in memory)
(Enter code [407] with digital keys)[START]
Forced performing of color registration control
*The larger the adjustment value, the shorter the distance C becomes (0.074 %/step = 0.15 mm/step).
(d) Secondary-scanning laser writing start position adjustment
1. While pressing the digital keys [0] and [5] simultaneously, turn ON the power.(Adjustment mode)
2. Press [1][PRINTER/NETWORK]. (A grid pattern with 10mm squares is printed out. Use A3/LD from
the 2nd cassette.)
3. Measure the distance D from the leading edge of the paper to the 6th grid line of the grid pattern.
4. Check if the distance D is within 55±0.5 mm or not.
5. If it is not, use the following procedure to change values and repeat step 2. to 4. above.
<Procedure> (Adjustment mode)(Enter code [474] with digital keys)[START]
(Enter a value (acceptable values: 1 to 15) with digital keys)
[SET] or [INTERRUPT] (Stored in memory)
(Enter code [407] with digital keys)[START]
Forced performing of color registration control
*The larger the adjustment value, the shorter the distance D becomes (0.6 mm/step).
Note: The reproduction ratio adjustment and the laser writing start position adjustment in the primary- and
secondary-scanning directions have a connection as shown below.
1. When 05-400 is adjusted, 05-401, 402, 403, 404, 410 and 474 are automatically adjusted.
2. When 05-401 is adjusted, 05-402, 403, 404, 410 and 474 are automatically adjusted.
3. When 05-406 is adjusted, 05-404 and 410 are automatically adjusted.
4. When 05-410 is adjusted, 05-404 is automatically adjusted.