Setting mode (08)
Accep-
Code Name Default table Contents
Proce-
value
dure
406 Image quality control 1 0 ~ 1 After printing is finished and the time set in 1
auto-start (standby time) 08-452 has passed, image quality control
will start when printing is started or the
energy saver key is pressed.
0: Disabled 1: Enabled
407 Image quality control 0 0 ~ 1 During continuous printing, image quality 1
auto-start (continuous printing) control is started for every print volume set
in 08-453.
0: Disabled 1: Enabled
408 Image quality control 1 0 ~ 1 When the accumulated print volume since 1
auto-start (accumulated the last image quality control has attained
print volume) the amount set in 08-455, image quality
control automatically starts after the current
printing job.
0: Disabled 1: Enabled
409 Image quality control 3 1 0 ~ 1 Auto-performing of image quality control 1
0: Disabled
1: Enabled (Performing 08-410,413)
410 Drum surface potential 1 0 ~ 1 Performing drum surface potential correction 1
correction control by drum thermistor detection temperature for
by drum temperature image quality control.
0: Disabled 1: Enabled
* This selection is reflected if ‘Image quality
controls 1 and 3 (08-400,409)’ have been
set to 1 (Enabled).
411 Image quality control 4 1 0 ~ 1 Auto-performing of image quality control 1
0: Disabled 1: Enabled
* If image quality control 2 (08-401) is 0 (Dis-
abled), this value must be set to 0 (Disabled).
413 Transfer roller bias correction 1 0 ~ 1 Performing transfer roller bias correction 1
control by temperature and by the temperature and humidity sensor for
humidity image quality control.
0: Disabled 1: Enabled
* This selection is reflected if ‘Image quality
controls 1 and 3 (08-400,409)’ have been
set to 1 (Enabled).
415 Image quality control 0 0 ~ 16 Accumulated total of CE1, CE2, CE4 1
abnormal detection (Max.16 times)
counter (Y) * Enabled when ‘Image quality control 3
display/0 clearing (08-401)’ is 1(Enabled).