Intel 480T Switch User Manual


 
18
Intel
®
NetStructure 480T Routing Switch User Guide
Determining the Switch Location
The 480T routing switch can be free standing or mounted in a
standard 19-inch equipment rack. Mounting brackets are supplied
with the switch.
When deciding where to install the switch, ensure that:
The switch is accessible and you can connect cables easily.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the side vents is not
restricted.
The switch has a minimum of 25 mm (1-inch) clearance.
Units are not stacked more than four high if the switch is free-
standing.
Installing the Switch
You can mount the switch in a rack or place it free-standing on a
tabletop.
Caution: Do not
suspend the switch
from under a table or
desk, or attach it to a
wall.
Rack Mounting
To rack mount the 480T routing switch:
1 Place the switch upright on a hard flat surface, with the front
facing you.
2 Remove the screws (4 each side) from the sides of the chassis
and retain for Step 4.
3 Place the mounting bracket over the mounting holes on one side
of the unit.