NetStructure™ 480T Routing Switch User Guide
Free-Standing
The 480T routing switch is supplied with four self-adhesive rubber
pads.
You can stack up to
four switches on top of
one another.
1 Apply the pads to the underside of the device by sticking a pad
in the marked area at each corner of the switch.
2 Place the devices on top of one another, ensuring that the cor-
ners align.
Connecting Equipment to the Console Port
For direct local management, connect to the console port. The 480T
routing switch console port settings are set as follows:
• Baud rate—9600
• Data bits—8
• Stop bit—1
• Parity—None
• Flow control—XON/XOFF
Be sure the terminal connected to the console port on the switch is
configured with the same settings. This procedure is described in the
documentation supplied with the terminal or terminal emulation
software.
Turning On the Switch
To turn on power to the switch, connect the AC power cable to the
switch and then to the power outlet. The switch has no on/off switch.
Checking the Installation
After plugging in the switch, the device performs a Power-On Self-
Test (POST).
During the POST, all ports are temporarily disabled, the packet LED
is off and the power LED is on. The MGMT LED flashes quickly
until the switch has successfully passed the POST, whereby it returns
to the slow flashing state for normal operation.