3-27
Configuration Menu
GPI Inputs Menu
The GPI Inputs Menu allows you to assign specific functions to
trigger the GPIs. Eight GPI inputs are provided. All of these accept
pulse-type inputs except Aux Tally Back, which is level-sensitive.
Functions available for assignment to the GPIs are
■ Miscellaneous (Aux Tally)
■ Keyframe Effects
■ Auto Transitions
■ Cuts
■ E-MEM registers
■ Frame Stores
The FUNCTION SELECT knob is always delegated to one of these
functions, as indicated in parentheses in the FUNCTION SELECT
knob label.
GPI SELECT — Selects the GPI input whose function is to be
assigned.
FUNCTION SELECT soft knob — Selects the appropriate function
based on what GPI assignment is chosen.
FUNCTION SELECT
(MISC)
GPI INPUTS MENU
config / inputs / gpi inputs
GPI
SELECT
KF
EFFECT
AUTO
TRANS E-MEMCUT
AUX BUS
= 1
PROGRAM
GPI
FRAME
STORE
AUX TALLY
BUS 1?
When the desired function is selected,
press PROGRAM GPI button to set the
selected GPI input to the
selected function
Choose from these 6 buttons to select various
categories of GPI functions. Then use the
FUNCTION SELECT knob to select a function
DISABLE
GPI
LOG CHAN
TALLY
AUX
TALLY
GPI 1
M/E 1 AUTO TRAN
M/E 1 CUT
RUN EFFECT
MASTER RECALL EFF - 26
GPI DISABLED
FRAME STORE VIDEO GRAB
SEQUENCE MODE
GPI 2
GPI 3
GPI 4
GPI 5
GPI 6
GPI 7
GPI 8
AUX TALLY - BUS 1
GPI 1
MISC