Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
552
Security
CHAP
Select "ON "to enable CHAP authentication for the target port. Select "OFF" to disable CHAP
authentication.
For CHAP authentication, an encrypted password based on a random key that the ETERNUS DX Disk
storage system receives from the host is sent, and connection possibility is judged on the server
side.
CHAP User Name
When "ON" is selected for "CHAP", enter the user name to access the target port. Make sure to set the
user name and password in pairs.
The following input conditions apply:
- Up to 63 alphanumeric characters and symbols
- Space
New Password
When "ON" is selected for "CHAP", enter the password to access the target port. Make sure to set the
user name and password in pairs.
The following input conditions apply:
- 12 - 32 alphanumeric characters and symbols
- Space
Confirm new Password
Specify the same password as that entered in the "New Password" field.
The following input conditions apply:
- 12 - 32 alphanumeric characters and symbols
- Space
REC Settings
REC Line No.
Select the REC line number of the target port.
The REC line number is used to switch the communication path when a line fails. The REC line
number is used to recognize failed lines. Set different REC line numbers for each physical
communication path. When lines are in normal status, an REC can be performed regardless of the
REC line number (specifying the same REC line numbers is allowed) in the same way as
conventional REC operations. Note that no priority applies to REC line numbers.
REC Transfer Mode
Select which REC transfer mode is enabled or disabled for the target port.
When "Enable" is selected, an REC is performed in the selected transfer mode for the target port.
When "Disable" is selected, an REC is not performed in the selected transfer mode for the target
port.
When a line fails, the communication path is switched according to the REC line number of the
copy source storage system. For normal operation, set the same REC line number for the copy
source and the copy destination storage systems to recover data.
If the port mode has been changed from "RA" to "CA", the REC line number returns to the
default setting ("0"). When the port mode has changed from "RA" to "CA/RA", the current REC
line number setting is retained. Refer to "9.2.3.11 Modify Port Mode" (page 571)
for details.