Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
882
• Display parts (except disk) with error status on LCD
Select "Enable" when displaying the part (other than disk) error message in the LCD, and select
"Disable" to not display the message in the LCD. This setting is available only when using the
ETERNUS DX8700 S2.
• Display parts (except disk) with warning status on LCD
Select "Enable" when displaying the part (other than disk) warning message in the LCD, and select
"Disable" to not display the message in the LCD. This setting is available only when using the
ETERNUS DX8700 S2.
• Display disks with error status on LCD
Select "Enable" when displaying the drive error message in the LCD for each condition shown below,
and select "Disable" to not display the message in the LCD. This setting is available only when using
the ETERNUS DX8700 S2.
- Any Time
Always notifies when a drive error occurs.
- when HS<0
Notifies only if a drive error occurs when available hot spare disk is " 0". This item can be selected
only when the "Display disks with error status on LCD (Any Time)" checkbox is cleared.
• Display disks with warning status on LCD
Select "Enable" when displaying the part (other than disk) warning message in the LCD, and select
"Disable" to not display the message in the LCD. This function is available only when using the
ETERNUS DX8700 S2.
- Any Time
Always notifies when a drive warning status occurs.
- when HS<0
Notifies only if a drive warning status occurs when available hot spare disk is " 0". This item can
be selected only when the "Display disks with warning status on LCD (Any Time)" checkbox is
cleared.
● Error Severity Level
Select whether to notify of the error event for each event type.
• Parts Error
Select whether to notify when a failure occurs in a part other than the drive. When notifying, select
the notification method.
• Disk Error
Select whether to notify when a drive failure occurs for each condition shown below. When
notifying, select the notification method.
- Any Time
Always notifies when a drive failure occurs.
- when HS<0
Notifies only if a drive failure occurs when available hot spare disk is " 0" (*1).
*1: When rebuilding cannot be performed because there are no hot spares that can be used as a
substitute for the failed drive.
For the ETERNUS DX8700 S2, whether to display the LCD message in the Overview screen and the LCD
panel on the Operation panel is determined by the notification setting that is specified for this
function.