Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
751
8 Click the [Done] button to return to the [Network] screen.
End of procedure
■ When using IPv6
The procedure to set network environment using IPv6 address is as follows:
Procedure
1 Click [Setup Network] in [Action].
2 Select the network port and specify each item.
● Select Network Port
• Network Port
Select the port to configure from "MNT", "RMT", and "FST".
- For ETERNUS DX80 S2/DX90 S2: MNT or RMT
- For ETERNUS DX410 S2/DX440 S2: MNT, RMT, or FST
- For ETERNUS DX8100 S2/DX8700 S2: MNT, RMT, or FST
● Interface
• Master IP Link Local Address
Input the link local address (interface ID) for the Master CM of the ETERNUS DX Disk storage system.
Note that the link local address is only available within the same network and cannot be connected
to the Internet. Connection via a router is not available.
Refer to "Available IPv6 Address" (page 757)
for details.
Note that the current setting is displayed by an abbreviation.
The following input condition applies:
- fe80::xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to "IPv6 Address Notation (Setup Network Environment)" (page 757)
for details.
• Master Connect IP Address
Input the connect IP address for the Master CM of the ETERNUS DX Disk storage system.
"Master Connect IP Address" corresponds to "Master IP Address" for IPv4.
The following IPv6 addresses can be used; "global address", "unique local address", and "6to4
address". Refer to "Available IPv6 Address" (page 757)
for details.
Note that the current setting is displayed by an abbreviation.
The following input condition applies:
- xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to "IPv6 Address Notation (Setup Network Environment)" (page 757)
for details.
Device management operation cannot be continued if the IP address of the ETERNUS DX Disk storage
system has been changed. Logging in again with the new IP address is required.