Raritan Computer 4.7 Switch User Manual


 
Chapter 7: Operation - Administrator Functions
109
Four-channel association is permitted for P2-UMT442,
P2-UMT832M, and P2-UMT1664M.
16-channel association is permitted for P2-UMT1664M alone.
Note: To obtain the 16-channel association capability, you must
upgrade the Paragon switch to version 4.7 or later, and use Paragon
Manager 2.0.4 or later.
The sequence of associated channels can be random.
Each channel port belongs to one association group only.
Only channel ports connected to servers are available for
association.
Up to 126 association groups are allowed per Paragon II system.
Limitations:
The Multiple Video function is not applicable to those channels which
share only one path via the tiered device, such as P2ZCIM,
P2CIM-APS2-B or P2CIM-AUSB-B (for IBM BladeCenter servers).
For 16-channel associations, the associated channel ports must be
on the Base Unit if your Paragon system is a multi-tier configuration.
User Configuration
To view the current connection status for each user and to add, delete,
and edit user names and security rights, select option 2, User
Configuration, from the Administration menu.