Raritan Computer 4.7 Switch User Manual


 
Chapter 10: Configurations
150
Non-Standard Tiered Configurations
Non-Standard tiered configurations are those configurations supported
by Paragon II, but require special procedure in order to function properly.
These include:
Triangle Configuration
Single Diamond Configuration
Redundant Configuration
FUNC Reset Guidelines for Reconnection
After any re-connection subsequent to the Non-Standard tiered
configuration, all Paragon switches should undergo a FUNC
reset to clear the database. See Reset Unit (on page 44) for
more info
rma
tion on clearing the database. This procedure
should be performed starting from the third-tier device down to
the Base Unit.
Whenever a third-tier Paragon switch is replaced, all of the
second-tier Paragon switches and Base Units should undergo a
FUNC reset.
Whenever a second-tier Paragon switch is replaced, all of the
Base Units should undergo a FUNC reset.
Whenever a base-tier Paragon switch (Base Unit) is replaced,
only the new Paragon switch should undergo a FUNC reset.