Raritan Computer 4.7 Switch User Manual


 
196
In This Chapter
Deployment Recommendations ............................................................196
Supported Resolutions on P2-EUST and P2-EUST/C
..........................197
Deployment Recommendations
In the Paragon II system, video quality is usually affected by these
factors:
Type of the user station: P2-UST, P2-EUST, or P2-EUST/C
UTP cable length between the user station and the CIM (server)
UTP cable type: Belden or non-Belden cable
P2-EUST and P2-EUST/C have the function of automatic skew
compensation when used with P2CIM-APS2, P2CIM-AUSB,
P2CIM-AUSB-C or P2CIM-ASUN, and thus provides better video quality
than P2-UST. Belden cable is proven to provide better video quality than
non-Belden cable in Raritan's lab. Therefore, our recommendation for
good or even excellent video quality is as follows:
With non-Belden cables
Cable length (feet) Deployment
0 ~ 1000 P2-EUST or P2-EUST/C*
With Belden cables
Cable length (feet) Deployment
500
P2-UST, P2-EUST or P2-EUST/C
501 ~ 1000 P2-EUST or P2-EUST/C*
* For P2-EUST or P2-EUST/C to provide automatic skew compensation,
make sure this user station is used with the appropriate CIM type:
P2CIM-APS2, P2CIM-AUSB, P2CIM-AUSB-C, P2CIM-APS2DUAL,
P2CIM-AUSBDUAL, P2CIM-ASUN, P2CIM-APS2-B, or P2CIM-AUSB-B.
Appendix C
Recommendation for Better Video
Quality