Raritan Computer 4.7 Switch User Manual


 
Appendix D: Connecting Serial Devices to Paragon II System
206
Configuring AUATC
Press Alt + F2 to activate the Setup Screen, where you can select your
desired serial-communication parameters (such as baud rate.) and
local/remote output. The initial parameters will always start at their
factory defaults, so make sure that the serial port or device to which
AUATC is attached is temporarily configured for 9600 bps, 8 data bits, no
parity, and 1 stop bit. (If the port or device cannot support all of these
settings, you must temporarily attach one that can.) Also, if you want to
perform initial configuration with a “local user station,” it must consist of a
PS/2 keyboard and a VGA monitor.
Available data-rate (“Baud Rate”) settings are 2400, 4800, 9600, and
19,200 bps. You can select even, odd, or no (“None”) parity; 7 or 8 data
bits; and 1 or 2 stop bits (but 7 data bits requires 2 stop bits). The
terminal type is fixed at VT100.
For local/remote connection, choose CAT 5&LOCAL if you connect the
AUATC both to a local monitor via the VGA HD15 connector and to
Raritan's Paragon switch via the Cat5 port (RJ45); choose LOCAL if the
unit is connected to a local monitor only.