Raritan Computer 4.7 Switch User Manual


 
Chapter 12: Firmware Upgrade
175
User Stations
The failsafe capability is a standard feature of P2-EUST and P2-EUST/C.
P2-UST with firmware version earlier than 1F9 does not have this feature.
For an older P2-UST, you can upgrade its firmware to get the failsafe
feature.
To update user stations for Failsafe Upgrade feature (P2-UST
Only)
The procedures are the same as those outlined in General Update
Procedure (on page 167). Note that the filename for upgrading the
P2-UST us
er station for failsafe capability is “V5_1F9.hex” or later.
To verify the firmware version
At the upgraded user station:
1. Activate the Paragon OSUI by pressing the hot key (default: Scroll
Lock) twice quickly.
2. Press F8 to display the user station's version information.
To recover user stations after upgrade failure
As long as your user station has the failsafe capability, you can restore
its function whenever the upgrade failure occurs.
1. Power cycle the user station.
2. Repeat the same upgrade process until the upgrade is finished
successfully.