ADC12 Registers
20-25ADC12
ADC12MCTLx, ADC12 Conversion Memory Control Registers
76543210
EOS SREFx INCHx
rw−(0) rw−(0) rw−(0) rw−(0) rw−(0) rw−(0) rw−(0) rw−(0)
Modifiable only when ENC = 0
EOS
Bit 7 End of sequence. Indicates the last conversion in a sequence.
0 Not end of sequence
1 End of sequence
SREFx
Bits
6-4
Select reference
000 V
R+
= AV
CC
and V
R−
= AV
SS
001 V
R+
= V
REF+
and V
R−
= AV
SS
010 V
R+
= Ve
REF+
and V
R−
= AV
SS
011 V
R+
= Ve
REF+
and V
R−
= AV
SS
100 V
R+
= AV
CC
and V
R−
= V
REF−
/ Ve
REF−
101 V
R+
= V
REF+
and V
R−
= V
REF−
/ Ve
REF−
110 V
R+
= Ve
REF+
and V
R−
= V
REF−
/ Ve
REF−
111 V
R+
= Ve
REF+
and V
R−
= V
REF−
/ Ve
REF−
INCHx
Bits
3-0
Input channel select
0000 A0
0001 A1
0010 A2
0011 A3
0100 A4
0101 A5
0110 A6
0111 A7
1000 Ve
REF+
1001 V
REF−
/Ve
REF−
1010 Temperature sensor
1011 (AV
CC
– AV
SS
) / 2
1100 (AV
CC
– AV
SS
) / 2, A12 on MSP430FG43x devices
1101 (AV
CC
– AV
SS
) / 2, A13 on MSP430FG43x devices
1110 (AV
CC
– AV
SS
) / 2, A14 on MSP430FG43x devices
1111 (AV
CC
– AV
SS
) / 2, A15 on MSP430FG43x devices