Chapter 19: Using the Telnet Viewer 265
left parenthesis and right parenthesis. The terminal type must be entered in the Terminal Type
field exactly as shown in Table 19.4.
To change the linefeed settings:
1. Select Options - Session Properties from the menu or click the Session Settings icon in the
toolbar. The Session Properties dialog box will appear.
2. Click the Terminal tab.
3. When connecting to devices that do not insert a carriage return in incoming or outgoing data,
automatically inserting a line after each line of data can prevent overwriting data when a new
line is received.
If the New Line Mode - Inbound box is checked, an inbound carriage return from the device
will be treated as if both a carriage return and a linefeed were received. If not checked, a
linefeed is not added to an inbound carriage return.
If the New Line Mode - Outbound box is checked, an outbound carriage return to the device
will always be followed by a linefeed character. If not checked, a linefeed is not sent with a
carriage return. The default value is disabled for inbound and outbound.
To enable/disable line wrap:
1. Select Options - Session Properties from the menu or click the Session Settings icon in the
toolbar. The Session Properties dialog box will appear.
2. Click the Terminal tab.
3. Enable or disable the Auto wrap line checkbox. When line wrap is enabled, characters wrap
onto the next line when a new character is received and the cursor is at the end of the line.
When disabled, new characters will overwrite the last character on the current line when the
cursor is at the end of the line. The default value is enabled.
To enable/disable local echo:
1. Select Options - Session Properties from the menu or click the Session Settings icon in the
toolbar. The Session Properties dialog box will appear.
Table 19.4: Terminal Emulation and Type
Terminal Emulation Terminal Type
VT52 DEC-VT52
VT100 DEC-VT100
VT100+ DEC-VT100
VT102 DEC-VT102
VT220 DEC-VT220
VT320 DEC-VT320